Used 60 Amp Square D HDP36060CTX Breaker

Manufacturer Square D
Type Breaker
Specifications
Unit # ACC384PA-PHILA
Manufacturer Square D
Type Breaker
Condition Used
Status Available
Additional Features

Used 60 Amp Square D HDP36060CTX Breaker

Part Number: GM47475-36

Serial Number: 0202462847730059

Main
Main
Range PowerPact
Product name PowerPact H
Product or Component Type Circuit breaker
Device Application Distribution
Complementary
Line Rated Current 60 A
Number of Poles 3P
Protected poles description 3t
Control Type Toggle
Breaking capacity code D
Breaking capacity 25 kA 240 V AC 50/60 Hz UL 489
18 kA 480 V AC 50/60 Hz
14 kA 600 V AC 50/60 Hz
20 kA 250 V DC
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-3
Network Frequency 50/60 Hz
[Ics] rated service breaking capacity 25 kA 220/240 V AC 50/60 Hz IEC 60947-2
18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2
14 kA 500/525 V AC 50/60 Hz IEC 60947-2
20 kA 250 V DC IEC 60947-2
20 kA 500 V DC IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Trip unit technology Thermal-magnetic
Magnetic tripping current 1450 A
Magnetic hold current 800 A
Continuous current rating 80 %
[Ui] rated insulation voltage 750 V IEC 60947-2
Suitability for isolation Yes IEC 60947-2
Utilisation category Category A
AWG gauge AWG 14…AWG 3/0 aluminium/copper terminal
Local signalling Switched off (OFF) 1 trip indicator green)
Mounting mode Unit mount lug)
Mounting Support Lug
Electrical connection Terminal nut line
Lugs load
Terminal identifier AL150HD
Tightening torque 44.25 lbf.in (5 N.m) 0.00…0.01 in² (2.5…6 mm²) (AWG 14…AWG 10)
123.91 lbf.in (14 N.m) 0.02…0.15 in² (10…95 mm²) (AWG 8…AWG 3/0)
Number of slots 2 auxiliary switch OF plug-in)
1 alarm switch SD plug-in)
1 overcurrent trip switch SDE plug-in)
1 voltage release MN or MX plug-in)
Power wire stripping length 0.63 in (16 mm)
Color Black
Height 6.42 in (163 mm)
Width 4.09 in (104 mm)
Depth 3.39 in (86 mm)
Net Weight 4.85 lb(US) (2.2 kg)
Quantity per Set 1
Communication interface Modbus
Ethernet
circuit breaker application HACR rated
Environment
Quality labels CE
Standards UL
CSA
NEMA
NOM-003-SCFI-2000
IEC 60947-2
Product certifications UL
CSA
NOM
IP degree of protection Front cover IP40 IEC 60529
Pollution degree 3 IEC 60947-1
Ambient Air Temperature for Operation 28…158 °F (-2…70 °C)
Ambient Air Temperature for Storage -58…185 °F (-50…85 °C)
Operating altitude < 6561.68 ft (2000 m) without derating
5000 m with derating

PowerPacT H-Frame Molded Case Circuit Breakers_HDP36060

Inquire about this Product

Have any questions about our commercial generators?

Contact Us Today