New 250 Amp Square D PowerPacT JDP36250CTX Breaker (30 Available)

Manufacturer Schneider Electric
Type Breaker
MFG Year 2023
Specifications
Unit # Multiple Units Available - Check Status
Manufacturer Schneider Electric
Type Breaker
MFG Year 2023
Condition New
Status Available
Additional Features

New 250 Amp Square D PowerPacT JDP36250CTX Breaker

ACC202PA-PHILA
ACC203PA-PHILA
ACC204PA-PHILA
ACC205PA-PHILA
ACC206PA-PHILA
ACC208PA-PHILA
ACC260PA-PHILA
ACC261PA-PHILA
ACC262PA-PHILA
ACC263PA-PHILA
ACC264PA-PHILA
ACC265PA-PHILA
ACC266PA-PHILA
ACC267PA-PHILA
ACC268PA-PHILA
ACC269PA-PHILA
ACC270PA-PHILA
ACC271PA-PHILA
ACC272PA-PHILA
ACC273PA-PHILA
ACC274PA-PHILA
ACC346PA-PHILA
ACC347PA-PHILA
ACC348PA-PHILA
ACC349PA-PHILA
ACC351PA-PHILA
ACC352PA-PHILA
ACC353PA-PHILA
ACC354PA-PHILA
ACC355PA-PHILA

Schneider Electric Part No: GM47476-13

Kohler Part No: GM79759-KP1

Compatible lugs for this unit are available for sale!

Main
Range PowerPact
Product name PowerPact J
Product or Component Type Circuit breaker
Device Application Distribution
Complementary
Line Rated Current 250 A
Number of Poles 3P
Control Type Toggle
Breaking capacity code D
Breaking capacity 25 kA 240 V AC 50/60 Hz UL 489
18 kA 480 V AC 50/60 Hz
14 kA 600 V AC 50/60 Hz
20 kA 250 V DC
[Ue] rated operational voltage 600 V AC 50/60 Hz IEC 60947-3
Network Frequency 50/60 Hz
[Ics] rated service breaking capacity 25 kA 220/240 V AC 50/60 Hz IEC 60947-2
18 kA 380/440/415 V AC 50/60 Hz IEC 60947-2
14 kA 500/525 V AC 50/60 Hz IEC 60947-2
20 kA 250 V DC IEC 60947-2
20 kA 500 V DC IEC 60947-2
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Trip unit technology Thermal-magnetic
Magnetic tripping current 2500 A
Magnetic hold current 1250 A
Continuous current rating 80 %
[Ui] rated insulation voltage 750 V IEC 60947-2
Protection Type Overload protection
Short-circuit protection
Suitability for isolation Yes IEC 60947-2
Utilisation category Category A
AWG gauge AWG 3/0…350 kcmil aluminium/copper terminals
Local signalling Switched off (OFF) 1 trip indicator green)
Mounting mode Unit mount lug)
Mounting Support Lug
Electrical connection Terminal nut line
Lugs load
Terminal identifier AL250JD
long time pick-up adjustment range 0.25…1 x In
Tightening torque 221.27 lbf.in (25 N.m) 0.15…0.29 in² (95…185 mm²) (AWG 3/0…350 kcmil)
Number of slots 2 auxiliary switch OF plug-in)
1 alarm switch SD plug-in)
1 overcurrent trip switch SDE plug-in)
1 voltage release MN or MX plug-in)
Power wire stripping length 0.98 in (25 mm)
Height 7.52 in (191 mm)
Width 4.09 in (104 mm)
Depth 3.39 in (86 mm)
Net Weight 5.29 lb(US) (2.4 kg)
Communication interface Modbus
Ethernet
Circuit breaker application HACR rated
Environment
Quality labels CE
standards UL
CSA
NEMA
NOM-003-SCFI-2000
IEC 60947-2
Product certifications UL
CSA
NOM
IP degree of protection Front cover IP40
Pollution degree 3 IEC 60947-1
Ambient Air Temperature for Operation 28…158 °F (-2…70 °C)
Ambient Air Temperature for Storage -58…185 °F (-50…85 °C)
Operating altitude < 6561.68 ft (2000 m) without derating
5000 m with derating
Ordering and shipping details
Category 01110-HD,JD UNIT MT BREAKER/SWITCH
Discount Schedule DE2
GTIN 785901947158
Returnability Yes
Country of origin MX
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 5.13 in (13.018 cm)
Package 1 Width 7.25 in (18.415 cm)
Package 1 Length 8.44 in (21.433 cm)
Package 1 Weight 4.84 lb(US) (2.195 kg)